MCB Schneider 1P 10A A9F74110 - ACTI9 IC60N

Mã hàng: MCB Schneider 1P 10A A9F74110 - ACTI9 IC60N
0/5 (0 Reviews)

iC60N MCB 1P, 6kA, 230V, C curve
Mã hàng : A9F74110
Hãng sản xuất: Schneider

Trạng thái sản phẩm

Còn Hàng

Giá: Liên Hệ

THÔNG SỐ KỸ THUẬT 

Main
Device application Distribution
Range Acti9
Product name Acti9 iC60
Product or component type Miniature circuit-breaker
Device short name IC60N
Poles description 1P
Number of protected poles 1
[In] rated current 10 A
Network type DC
AC
Trip unit technology Thermal-magnetic
Curve code C
Breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2
15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2
10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2
20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilisation category Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2
Suitability for isolation Yes conforming to EN 60898-1
Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2
Standards IEC 60947-2
EN 60898-1
IEC 60898-1
EN 60947-2
Complementary
Network frequency 50/60 Hz
Magnetic tripping limit 8 x In +/- 20 %
[Ics] rated service breaking capacity 27 kA 75 % conforming to EN 60947-2 - 12...60 V AC 50/60 Hz
7.5 kA 75 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz
27 kA 75 % conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz
7.5 kA 75 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz
15 kA 75 % conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz
15 kA 75 % conforming to EN 60947-2 - 100...133 V AC 50/60 Hz
6000 A 100 % conforming to EN 60898-1 - 230 V AC 50/60 Hz
6000 A 100 % conforming to IEC 60898-1 - 230 V AC 50/60 Hz
10 kA 100 % conforming to EN 60947-2 - 72 V DC
10 kA 100 % conforming to IEC 60947-2 - 72 V DC
15 kA 100 % conforming to EN 60947-2 - 12...60 V DC
15 kA 100 % conforming to IEC 60947-2 - 12...60 V DC
Limitation class 3 conforming to EN 60898-1
3 conforming to IEC 60898-1
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2
Contact position indicator Yes
Control type Toggle
local signalling Trip indicator
Mounting mode Fixed
mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES
9 mm pitches 2
height 85 mm
Width 18 mm
Depth 78.5 mm
Net weight 0.215 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections - terminals Single terminal (top or bottom) 1…25 mm² rigid
Single terminal (top or bottom) 1…16 mm² flexible
Wire stripping length 14 mm for top or bottom connection
Tightening torque 2 N.m top or bottom
earth-leakage protection Without
Environment
IP degree of protection IP20 conforming to IEC 60529
IP20 conforming to EN 60529
Pollution degree 3 conforming to EN 60947-2
3 conforming to IEC 60947-2
Overvoltage category IV
Tropicalisation 2 conforming to IEC 60068-1
Relative humidity 95 % at 55 °C
Operating altitude 0...2000 m
ambient air temperature for operation -35…70 °C
Ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 2.000 cm
Package 1 Width 7.500 cm
Package 1 Length 9.500 cm
Package 1 Weight 106.700 g
Unit Type of Package 2 BB1
Number of Units in Package 2 12
Package 2 Height 8.500 cm
Package 2 Width 10.000 cm
Package 2 Length 22.000 cm
Package 2 Weight 1.372 kg
Unit Type of Package 3 S03
Number of Units in Package 3 132
Package 3 Height 30.000 cm
Package 3 Width 30.000 cm
Package 3 Length 40.000 cm
Package 3 Weight 15.508 kg
Contractual warranty
Warranty 18 months

Sản Phẩm Liên Quan

Bài Viết Mới Nhất

So Sánh SINAMICS G120 Với Các Dòng Biến Tần Siemens Khác

So Sánh SINAMICS G120 Với Các Dòng Biến Tần Siemens Khác

16 - 11 - 2024

Biến Tần Siemens SINAMICS V20

Biến Tần Siemens SINAMICS V20

13 - 11 - 2024

Lợi Ích Của Khởi Động Mềm Trong Ứng Dụng Công Nghiệp

Lợi Ích Của Khởi Động Mềm Trong Ứng Dụng Công Nghiệp

08 - 11 - 2024

Hướng dẫn lựa chọn màn hình điều khiển cảm ứng HMI

Hướng dẫn lựa chọn màn hình điều khiển cảm ứng HMI

04 - 11 - 2024

Tư vấn lắp đặt hệ thống mạng công nghiệp Ethernet

Tư vấn lắp đặt hệ thống mạng công nghiệp Ethernet

01 - 11 - 2024

Các Yếu Tố Cần Cân Nhắc Khi Mua Bộ Nguồn DC

Các Yếu Tố Cần Cân Nhắc Khi Mua Bộ Nguồn DC

28 - 10 - 2024

Tại Sao Hệ Thống Tự Động Hóa Cần UPS Dự Phòng?

Tại Sao Hệ Thống Tự Động Hóa Cần UPS Dự Phòng?

23 - 10 - 2024